[Revision: April 15, 1998, 0-215-006, ©Rytec Corporation]DigitalGatewayInstallation &Owners ManualModel DG1200®
4INPUTS TO THE DIGITAL GATEWAYAC INPUTS (Figure 3)NOTE: All AC inputs should be contact closure orsolid state connections only. RC networks,MOV's
5To reset the system and leave the door open:Activate the Stop input or push the Open Jog/Resetbutton on the Digital Gateway. The system will resetand
6DC INPUTS (Figure 4)A0500027DC InputsDC InputsFigure 4NOTE: All DC inputs should be contact closure orNPN open collector only. RC networks,MOV's
7TIMERS (Figure 5)CLOSE Backup TimerOPEN Backup TimerAuto CloseTimerA/A CloseDelay TimerA/A Close Delay Timer—ON/OFF ButtonA0500027Figure 5NOTE: The t
8AUTO CLOSE DELAY TIMERThis timer delays the closing of the door when it isopened by an Auto input activator (terminal 14) orfloor loop (terminal 30).
9ALARM CONDITIONSCOnnECt, MISSING CONNECTIONSThe Digital Gateway monitors the N.C. inputs uponpower-up. The alarm indicates one or more missingrequire
10CL = 0, CLOSE TIME EXCEEDEDThis alarm indicates that the close backup timer hastimed out before the door has fully closed and thedoor has not operat
11A0500027EdGEFigure 13NON-ALARM CONDITIONSHELLO, SAFE START-UPWhen power is applied to the Digital Gateway the doorwill not move regardless of the st
12LOC, IDLE STATEThis message will be displayed when input 24 isactivated, the door is fully closed (on the closed limitswitch) and the Digital Gatewa
13REPLACEMENTThe fused disconnect must be in the OFFposition and properly locked and taggedbefore performing the following proce-dure.If the Digital G
14PROGRAM 2, INPUT 24This input can be used to place the Digital Gatewayinto an inactive condition, operate the door manuallyor automatically or open
15PROGRAM 4, PROGRAMMABLE OPTIONSThis program section allows you to change the Openand Close inputs to constant pressure/jog, set areverse delay timer
161. To enter into the programming mode press andhold both the Open and Close Backup Timebuttons for three seconds. The display will changeto three 0&
176. For the remaining programs use the Select buttonto scroll through the options. Use the UP andDOWN arrow keys to set the time or option andthe Set
18WIRING SCHEMATICSFAST-SEAL—ONE-SPEED DIGITAL GATEWAY (E4200)111- POWER- AC CONTROL- DC CONTROL- FLOOR LOOPTERMINAL BLOCKSBLACKREDBLUEBEIGEGREEN/YELL
19FAST-FOLD—TWO-SPEED DIGITAL GATEWAY (E4100)A1500143NOTE: This schematic is for general infor-mation only. Due to varying require-ments for individua
20PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)WIRING SCHEMATICS—PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)A7500148NOTE: This schematic is for general
TABLE OF CONTENTSPAG EHOW TO USE MANUAL... 1INTRODUCTION ...
DC INPUTS ... 6Photoeye—Terminal 15 ...
PAG EPROGRAM 2, INPUT 24 ... 14LOC Condition ...
This page intentionally left blank.
1HOW TO USE MANUALHOW TO USE MANUALThroughout this manual, the following key words areused to alert the reader of potential hazardoussituations, or si
2INTRODUCTIONINTRODUCTIONYour door control box is equipped with Rytec's DigitalGateway® which is a state of the art, solid statemicroprocessor-ba
3EXPLANATION OF DIGITAL GATEWAYCONTROLSTERMINAL STRIPThe Digital Gateway has plug-in terminal strips alongthe left side of the unit. The power, output
Komentáře k této Příručce